[1]章德昆 陈婷婷 陈 魁 王力群 龚 超 李 嵩 夏垚坤 陈敬华.一种用于microRNA-21浓度检测的荧光传感方法的建立[J].福建医药杂志,2020,42(01):132-134.
 ZHANG Dekun,CHEN Tingting,CHEN Kui,et al.Establishment of a fluorescence sensing method for microRNA-21 concentration detection[J].FUJIAN MEDICAL JOURNAL,2020,42(01):132-134.
点击复制

一种用于microRNA-21浓度检测的荧光传感方法的建立()
分享到:

《福建医药杂志》[ISSN:1002-2600/CN:35-1071/R]

卷:
42
期数:
2020年01期
页码:
132-134
栏目:
基础研究
出版日期:
2020-03-30

文章信息/Info

Title:
Establishment of a fluorescence sensing method for microRNA-21 concentration detection
文章编号:
1002-2600(2020)01-0132-03
作者:
章德昆1 陈婷婷2 陈 魁 王力群 龚 超 李 嵩 夏垚坤2 陈敬华2
福建医科大学附属福州市第一医院(福州 350009)
Author(s):
ZHANG Dekun CHEN Tingting CHEN Kui WANG Liqun GONG Chao LI Song XIA Yaokun CHEN Jinghua.
The Affiliated Fuzhou Municipal First Hospital of Fujian Medical University, Fuzhou,Fujian 350009, China
关键词:
聚多巴胺纳米粒子 miRNA-21 DNA探针 荧光检测
Keywords:
polydopamine nanoparticles miRNA-21 DNA probe fluorescence detection
分类号:
R917
文献标志码:
A
摘要:
目的 建立一种用于microRNA-21(miRNA-21)浓度检测的,基于聚多巴胺纳米粒子(PDANs)的荧光传感方法。方法 Ce6标记的捕获探针(Ce6-DNA)在Ca2+的介导下吸附在PDANs表面,荧光被猝灭。miRNA-21和Ce6-DNA杂交后,使其从PDANs表面解吸附,荧光恢复。利用荧光分光光度计分析靶标和Ce6-DNA反应前后荧光强度的变化,实现对miRNA-21的检测。结果 在5.0~200 nM范围内,670 nm处的荧光强度和miRNA-21的浓度呈良好的线性关系,检测限为1.80 nM。结论 基于Ce6-DNA功能化的PDANs可为miRNA-21的定量检测提供一种简单、准确、成本低、分析速度快的新方法。
Abstract:
Objective To develop a fluorescent method based on polydopamine nanoparticles(PDANs)for microRNA-21(miRNA-21)concentration detection. Methods Ce6-labeled capture probe(Ce6-DNA)was absorbed on the surface of PDANs through Ca2+ mediation, which resulted in the fluorescence of Ce6 being quenched. However, the Ce6-DNA was desorbed from PDANs when it hybridized with miRNA-21, which led to the recovery of fluorescence. This method could detect miRNA-21 quantitatively through measuring the change of fluorescence intensity using fluorescent spectrophotometer. Results There was a good linear relationship between the fluorescence intensity at 670 nm and miRNA-21 concentration from 5.0 to 200 nM. The limit of detection was 1.80 nM. Conclusion The Ce6-DNA functionalized PDANs can provide a simple, accurate, low-cost, and rapid novel method for miRNA-21 detection.

参考文献/References:

[1] Zhang Y, Mi X, Tan X, et al.Recent progress on liquid biopsy analysis using surface-enhanced Raman spectroscopy[J]. Theranostics, 2019, 9(2): 491-525.
[2] Abe F, Kitadate A, Ikeda S, et al.Histone deacetylase inhibitors inhibit metastasis by restoring a tumor suppressive microRNA-150 in advanced cutaneous T-cell lymphoma[J]. Oncotarget, 2017, 8(5): 7572-7585.
[3] Kim S W, Li Z, Moore P S, et al.A sensitive non-radioactive northern blot method to detect small RNAs[J]. Nucleic Acids Res,2010,38(7):e98.
[4] Qiang W, Li W, Li X, et al.Bioinspired polydopamine nanospheres: a superquencher for fluorescence sensing of biomolecules[J]. Chem Sci, 2014, 5(8): 3018-3024.
[5] Qiang W, Hu H, Sun L, et al.Aptamer/polydopamine nanospheres nanocomplex for in situ molecular sensing in living cells[J]. Anal Chem, 2015, 87(24): 12190-12196.
[6] Meng Y, Liu P, Zhou W, et al.Bioorthogonal DNA adsorption on polydopamine nanoparticles mediated by metal coordination for highly robust sensing in serum and living cells[J]. ACS Nano, 2018, 12(9): 9070-9080.
[7] Deng K, Chen Y, Li C, et al.808 nm light responsive nanotheranostic agents based on near-infrared dye functionalized manganese ferrite for magnetic-targeted and imaging-guided photodynamic/photothermal therapy[J]. J Mater Chem B, 2017, 5(9): 1803-1814.
[8] Siravegna G, Marsoni S, Siena S, et al.Integrating liquid biopsies into the management of cancer[J].Nat Rev Clin Oncol, 2017, 14(9): 531-548.
[9] Pirritano M, Fehlmann T, Laufer T, et al.Next generation sequencing analysis of total small noncoding RNAs from low input RNA from dried blood sampling[J].Anal Chem, 2018, 90(20): 11791-11796.
[10] Xia Y, Wang L, Li J, et al.A ratiometric fluorescent bioprobe based on carbon dots and acridone derivate for signal amplification detection exosomal microRNA[J]. Anal Chem, 2018, 90(15): 8969-8976.
[11] Wang C, Huang X, Tian X, et al.A multiplexed FRET aptasensor for the simultaneous detection of mycotoxins with magnetically controlled graphene oxide/Fe3O4 as a single energy acceptor[J]. Analyst, 2019, 144(20): 6004-6010.

备注/Memo

备注/Memo:
基金项目:福建省自然科学基金(2017J01226)1 Email:13809500062@139.com; 2 福建医科大学药学院
更新日期/Last Update: 2020-03-30